TROUBLESHOOTING
PROBLEM PROBABLE CAUSE WHAT TO DO
Poor or no flow from needles Sensor LED is lit when holding
your hand under it:
1. No water in the bottle Fill bottle with solution
2. Excessive air in the tubing Bleed air from tubing
3. Tip of the needle is excessively Replace
worn
4. Control valve is closed Open
5. Needle is not in contact with Adjust
the sheet
6. Solids trapped in needles Remove the needles from the nozzles
and blow out the needles with an air
compressor
Sensor LED not lit when holding
your hand under it:
1. WetScore unplugged Plug in outlet
2. Malfunction in Modulated Amp. Contact your dealer Rep.
Solution leaks at needle/nozzle
connection
1. Needle is cracked Replace
2. Needle is not securely Tighten
fastened to nozzle
Sheet is excessively wet,
score not a fine line
1. Flow rate is to great Adjust control valve for
proper flow
2. Needle is to large for light Change to smaller guage needle
weight sheet
3. To much water in solution Remix solution using
greater amount of alcohol
4. Coating of sheet is to great Recommend use of mechanical scoring
for WetScore use